Skip to product information
1 of 9

SMAS HIFU Super Lift Mini 2 Machine

SMAS HIFU Super Lift Mini 2 Machine

SKU:HIFU Super Lift mini-2

Regular price €9.190,00
Regular price Sale price €9.190,00
Sale Sold out
Shipping calculated at checkout.

VAT not included

Quantity

High-Precision Portable HIFU Platform for Facial Lifting and Body Contouring

Elevate structural rejuvenation treatments in your practice, double the performance of your technical consumables, and equip your treatment room with the most flexible High-Intensity Focused Ultrasound (HIFU) technology on the market, thanks to the SMAS Super-Lift Mini 2 Machine by Alvi Prague. This advanced tabletop hardware has been meticulously designed with feedback from aesthetic doctors to offer a deep, immediate, and progressive lift without resorting to surgical procedures. It is the perfect compact station for advanced clinics and beauty salons that want to maximize the profitability of their stock by combining high productivity with first-class clinical results.

With a compact, modern, and highly ergonomic chassis measuring **38 x 39 x 33 cm** (optimized net weight of 13.3 kg and 26.7 kg gross in its reinforced industrial packaging of 59.5 x 53.5 x 45.5 cm), this device sits excellently on any technical table or treatment cart. The ecosystem is equipped with a crisp LCD screen that allows visualization of target anatomical areas and interactive adjustment of power and pulse settings. It operates cleanly when connected to conventional **220-240 V / 50 Hz** networks with ultra-efficient power consumption of **100 W or less**, backed by certified **IP31 protection class** shielding against humidity in the cabin.

Advanced Synergistic Effect: Thermal Coagulation at 70°C and SMAS Cumulative Effect

The biggest drawback of conventional tightening treatments is their inability to reach the muscle plane, limiting their action to the more superficial layers of the epidermis. The SMAS Super-Lift Mini 2 platform excellently solves this through its intelligent software: it emits high-precision ultrasound waves that pass cleanly and harmlessly through the skin, concentrating thermal energy at specific points with a **1 mm** adjustment step. By generating strict localized heat between **60 and 70 °C**, the hardware causes immediate collagen contraction and activates the natural synthesis of new elastic fibers. The impact reaches the **SMAS** layer (superficial muscular aponeurosis), achieving a deep structural tightening whose results are immediately visible, progress elastically for up to 90 days, and remain stable between 1 and 3 years.

Ecosystem of 7 High-Fidelity Cartridges and 20,000 Lines of Resource

To precisely address any dermoesthetic alteration in patients aged 30 to 65, the hardware includes a complete set of **7 differentiated transducers**. Each nozzle offers an industrial resource of **20,000 lines of sonic impulses** (twice that of other equipment on the market), guaranteeing strict savings on consumables:

  • Facial and Periorbital Line (1.5 mm, 2 mm, 3 mm, and 4.5 mm): Allows for the elastic design of facial rejuvenation maps. Eliminates expression wrinkles, nasolabial folds, lifts the corner of the jaw, and achieves a crisp lift of the double chin, cheeks, and neck. The **2 mm** transducer is a unique tool for treating thin skin areas with total safety.
  • Advanced Body Line (6 mm, 9 mm, and 13 mm): Specifically designed to penetrate deep soft tissues, stimulating the natural lipolysis of localized fat reliefs and expressively increasing density and turgor in body contours.

High-Demand Clinical and Dermoesthetic Indications

  • Gravitational Ptosis and Loss of Facial Oval: Tightens and redefines sagging features, eliminating the appearance of fatigue and neck flaccidity.
  • Wrinkles, Folds, and Skin Aging: Smooths pronounced furrows and cleanly restores the elasticity and firmness of the epidermis.
  • Localized Fat Reliefs and Uneven Texture: Compacts the subcutaneous body plane in arms, abdomen, or hips, reducing the volume of adipose tissue.

Table of Technical Specifications and Official Parameters

Hardware Specification Value / Official Range Operational Performance in Your Cabin
Main Technology HIFU (High-Intensity Focused Ultrasound) 100% non-invasive and painless SMAS muscle layer lifting.
Exposure Temperature 60 - 70 °C (Degrees Celsius) Ideal thermal range for cleanly denaturing old collagen.
Impact Adjustment Step 1 mm (Micro-coagulation points) Millimeter-precise and safe distribution that preserves surrounding tissue.
Transducer Lifespan 20,000 impulse lines per nozzle Double storage capacity; maximum profitability per session.
Transducer Range 1.5 mm / 2 mm / 3 mm / 4.5 mm / 6 mm / 9 mm / 13 mm 7 depths of action for comprehensive face and body treatment.
Total Power Consumption ≤ 100 W (Power supply: 220-240V / 50 Hz) High-efficiency eco-friendly hardware; cool performance in the room.
Structural Safety IP31 Protection Class Shielded chassis against liquid ingress and galvanic network spikes.

Technical Application Protocol in Clinic (Step by Step):

  1. Hygiene and Geometric Marking: Perfectly and cleanly clean the patient's epidermis. Use a white demographic pencil to delimit treatment areas, tracing safety lines and elastic traction vectors. Strictly avoid areas of emergence of facial motor nerves.
  2. Application of Base Gel and Technical Selection: Apply a generous layer of clear ultrasonic conductive gel on clean skin. Turn on the SMAS Super-Lift Mini 2 unit and select the appropriate transducer on the screen according to the required depth (e.g., start with the 4.5 mm cartridge to treat the SMAS layer on the cheeks and continue cleanly with the 3 mm or 2 mm one).
  3. Ultrasonic Emission Phase: Place the manipulator nozzle completely perpendicularly and firmly on the skin, ensuring excellent contact. Activate the shot: the head will emit an automatic line of thermal points at 60-70 °C. The patient will only experience a sensation of internal warmth and tolerable tingling. Move the handpiece following the strict 1 mm step.
  4. Express Protocol Closure: After completing the protocol lines (the session can last from 30 minutes to 2 hours depending on the extension), cleanly remove any remaining gel. The complexion will show a subtle, transient, benign erythema and an immediate lifting effect. Apply a regenerating and photoprotective serum. The patient will immediately return to their normal routine. Clean and disinfect the nozzle thoroughly.
💡 Pro Tip: The most frequent operational error when starting out with HIFU technology using the Super-Lift Mini 2 system is maintaining the maximum automatic shot line length when working on curved or narrow bony reliefs, such as the zygomatic arch, mandibular border, or forehead. If the transducer loses flat contact with the skin mid-stroke due to bony curvature, the ultrasonic energy will be incorrectly concentrated, hitting the periosteum. This generates acute and unnecessary pain for the patient and reduces the effectiveness of the tightening. **Use the interactive screen software to elastically reduce the length of the impulse line in these complex areas and maintain homogeneous pressure**. This rigorous technical detail will ensure excellent comfort, avoid post-treatment discomfort, and consolidate the international prestige of your advanced practice.

Official Training and Certification Included: Alvi Prague offers free training with an official certificate upon purchase of the hardware, ensuring that your operators master the recommended protocols safely and professionally. Estimated delivery time of 7 to 10 business days directly from the factory to your business door!

Click "Add to Cart," introduce the versatility of the 7 HIFU transducers into your clinic protocols, multiply your business's profitability with the 20,000-line resource, and rejuvenate your patients with the structural precision of the SMAS Super-Lift Mini 2 Machine.

View full details