Skip to product information
1 of 11

PX-4000 plus needle-free radiofrequency and carboxytherapy machine

PX-4000 plus needle-free radiofrequency and carboxytherapy machine

SKU:PX-4000 plus

Regular price €2.600,00
Regular price Sale price €2.600,00
Sale Sold out
Shipping calculated at checkout.

VAT not included

Quantity

Thermolytic Radiofrequency and Non-Invasive Carboxytherapy System

Maximize your clinic's service menu, eliminate painful treatments that drive away your patients, and equip your practice with a high-fidelity European standard thanks to the Alvi Prague Needle-Free Radiofrequency and Carboxytherapy Machine. This sophisticated tabletop platform cleanly unifies electromagnetic thermal induction with the powerful transdermal Bohr effect. Meticulously designed for advanced centers that demand maximum profitability with minimal stock, this station executes biological lifting, cellular oxygenation, and body remodeling protocols without needles, without inflicting injuries, and without requiring medical rest.

With a high-strength modular chassis measuring **31.5 x 31.5 x 16.7 cm** and an optimized net weight of **6.6 kg** (8.25 kg gross with its protective packaging box of 54.5 x 38 x 25.5 cm), the equipment sits solidly on any technical table. Its interactive touch panel allows for flexible parameter configuration through pre-configured programs and a digital timer from **1 to 99 minutes**. Rigorously certified under strict European Union standards (official CE Certification), the hardware operates connected to **220-240 V / 50 Hz** electrical networks with ultra-efficient energy consumption of only **45 W or less**, under an **IP20 protection class**.

Advanced Synergistic Effect: The Power of Thermal Stimulation and the CO₂ Foaming Effect

The great competitive advantage of this Alvi Prague station lies in its ability to coordinate variable electromagnetic stimulation with a controlled biochemical reaction on the skin surface:

  • High-Precision Thermolytic Radiofrequency (0.5-3 MHz): Emits a variable electromagnetic field that operates at a flexible frequency of **0.5 to 3 MHz** with an exposure energy of **15 to 40 J/cm²** (adjustable in 17 power levels). It features an integrated temperature sensor that monitors tissue heating, forcing immediate contraction of collagen fibers, promoting lipolysis, and accelerating cellular regeneration cleanly.
  • Needle-Free Carboxytherapy by Sonic Vibration (300 Hz): The handpiece generates a strict mechanical vibration of **300 Hz** that interacts with a technical compound of sodium bicarbonate and citric acid. Upon contact with the skin, it produces a massive foaming effect that releases carbon dioxide ($CO_2$), inducing a reflexive hyperemia and deep transdermal oxygenation (Bohr Effect) that eliminates impurities, lightens blemishes, and destroys localized adiposity.

High-Demand Clinical and Dermoesthetic Indications

  • Skin Laxity, Wrinkles, and Premature Aging: Clearly activates the synthesis of new collagen, tightens fibrous septa, and performs a long-lasting non-surgical lift.
  • Localized Adiposity, Cellulite, and Contour Remodeling: Promotes the degradation of fat deposits and stimulates combined lymphatic microcirculation to reduce contours.
  • Contaminated Pores, Dehydrated Skin, and Dullness: Gently exfoliates keratinized layers, cleanly dislodges comedones, and impeccably restores natural color and tone.

Technical Specifications and Official Parameters Table

Hardware Module Configuration and Official Parameters Clinical Performance in your Box
Radiofrequency Module Frequency: 0.5 - 3 MHz | Energy: 15 - 40 J/cm² Thermal lifting, elastic collagen synthesis, and express cellular lipolysis.
RF Thermal Sensor Automatic monitoring and regulation on skin Strict burn prevention; clear homogeneous heat control.
Carboxytherapy Module Vibration frequency: 300 Hz Foaming effect releasing $CO_2$ for needle-free tissue oxygenation.
Energy Consumption ≤ 45 W (Power supply: 220-240 V / 50 Hz) Eco-friendly hardware with low consumption; cool operation and high profitability.
Electrical Safety IP20 Protection Class | Complies with EU standards Robust shielding against galvanic variations and network interference.

Technical Application Protocol in Treatment Room (Step-by-Step):

  1. Hygiene and Active Chemical Preparation: Thoroughly clean the skin surface to be treated. Apply the citric acid-based gel to the area and place the reactive sodium bicarbonate tablet in the special carboxytherapy handpiece.
  2. Transdermal Oxygenation by Carboxytherapy (300 Hz): Turn on the carboxytherapy module and set the express time on the touch panel. Move the head in continuous circular motions; the 300 Hz sonic vibration will accelerate the foaming effect, releasing dense microbubbles of $CO_2$. This saturation will force the body to send a clear rush of oxygen to the treated area, dislodging pores and impeccably lightening blemishes. Remove residues and clean the area thoroughly.
  3. Thermal Lifting by Radiofrequency: Apply the specific conductive gel for thermal treatments. Select the RF lifting function on the interface (adjusting the frequency between 0.5 and 3 MHz depending on whether it's for the face or body). Flexibly calibrate the power level (1 to 17) and move the handpiece with clear ascending vectorial passes. The integrated sensor will ensure that the tissue maintains an optimal target temperature of **40-42 °C** for collagen remodeling.
  4. Protocol Closure and Express Evaluation: At the end of the session, cleanly remove any remaining conductive gel. The patient will show visibly firmer, brighter, and more hydrated skin from this first application, without inflammatory marks, allowing them to return to their activities immediately.
💡 Pro Tip: The most common operational error when performing radiofrequency with this system is moving the handpiece too quickly for fear of causing a local burn, which prevents the tissue from reaching the **40-42 °C** necessary to break the transient hydrogen bonds of collagen. Since this Alvi Prague hardware has a real-time temperature sensor, **observe the digital screen and move the transducer with slow, concentrated circular motions until the target temperature is stabilized in the area; once achieved, maintain it by performing constant passes for 3-5 minutes per quadrant cleanly**. This strict methodological rigor will ensure excellent collagen synthesis, avoid electromagnetic energy waste, and consolidate the international prestige of your advanced center.

Engineering Guarantee and Professional Training: Alvi Prague provides permanent technical support for this equipment and offers advanced professional technical training services on demand, training your staff in the flexible design of highly effective commercial non-invasive combined protocols.

Click "Add to cart," integrate the dual biological power of Alvi Prague needle-free radiofrequency and carboxytherapy into your catalog, eliminate complex maintenance costs, and position your clinic at the forefront of non-invasive medical aesthetics.

View full details