T-18 Electrolysis and Electrocoagulation Machine
T-18 Electrolysis and Electrocoagulation Machine
SKU:T-18
VAT not included
Couldn't load pickup availability
Alvi Prague T-18 Electrolysis and Electrocoagulation Machine | Advanced High-Frequency Thermolysis and Lesion Cauterization Clinical Platform
Optimize your dermatological minor surgery services, ensure the definitive eradication of light-resistant hair, and equip your technical table with a bioelectrical precision station thanks to the Alvi Prague T-18 Electrolysis and Electrocoagulation Machine. This advanced professional platform cleanly combines high-power radiofrequency for galvanic hair removal and thermal electrocoagulation current. An excellent synergy that allows for quick, safe, and minimally invasive removal of both benign neoplasms and stubborn hair follicles, consolidating it as a flexible and indispensable tool for medical clinics, dermatologists, and premium aesthetic centers.
With an ultra-compact, ergonomic, and sleek chassis measuring **30 x 23 x 6 cm** and an optimized net weight of only 2.85 kg (3.5 kg gross with its reinforced packaging of 41 x 29 x 16 cm), the T-18 model integrates perfectly into any workspace without cluttering the technical table. The hardware includes a special adapter for multiple cascading connections with other units from Alvi Prague's renowned T Series. Designed under demanding international regulations, it operates connected to **220-240 V / 50 Hz** electrical grids with an ultra-efficient energy consumption of only **15 W or less**, supported by an isolation certification with **IP20 protection class** and mechanical safety locks.
Advanced Synergistic Effect: High-Frequency Thermolysis and Preventive Vascular Cauterization
The main drawback of conventional laser hair removal treatments is their ineffectiveness on gray, red, or melanin-deficient hair, as well as the risk of hyperpigmentation in darker skin types. The Alvi Prague T-18 station excellently solves this through its two physical modes of surgical precision:
- Electroepilation Module (Thermolysis at 1.695 MHz): The equipment generates a high-frequency alternating electric current of **1.695 MHz** which is transmitted millimetrically through an ultra-fine disposable needle directly to the follicle. Molecular oscillation produces localized instant heat that irreversibly destroys the dermal papilla and hair stem cells. It is a 100% effective method that permanently stops hair growth without damaging surrounding healthy tissues.
- Electrocoagulation Module (Cauterization at 18 kHz): For the removal of benign skin lesions, papillomas, warts, and skin tags, the system emits an **18 kHz** wave. This high-temperature current instantly seals blood vessels when cutting, minimizing bleeding, preventing express post-procedure infections, and reducing complication risks. Unlike destructive ablative techniques, this method allows for clean removal of the neoplasm to send the intact sample for pathological histological analysis.
Complete Work Ecosystem and Standard Surgical Instruments
To ensure flexible operation and cost-effective performance from day one, the hardware includes a complete industrial kit of high-fidelity accessories:
- Dual Specialized Handpieces: Includes an electrode holder handpiece for ablative electrodes and an ergonomic, high-sensitivity handpiece for electroepilation needles.
- Express Activation Pedal and Technical Support: Reinforced control pedal for high-precision hands-free firing, accompanied by 5 acrylic organizing shelves for the handpieces.
- Disposable Consumables Ecosystem: Supplied as standard with a complete set of electrodes for electrocoagulation and disposable needles for electroepilation.
High-Demand Clinical and Dermatological Indications
- Permanent Removal of Resistant Hair: Definitive treatment for facial and body hair without restrictions on color, thickness, or skin phototype (ideal for eyebrows, chin, and stubborn hair).
- Removal of Benign Neoplasms and Defects: Single-session removal of warts, papillomas, soft fibromas, superficial keratoses, and other skin imperfections.
- Express Vascular Control and Prophylaxis: Coagulation of micro-vessels that prevents bleeding and promotes aesthetic and rapid epidermal healing at any time of year.
Table of Technical Specifications and Official Parameters
| Hardware Specification | Official Value / Configuration | Operational Performance in Your Practice |
|---|---|---|
| Integrated Technologies | Electroepilation (Thermolysis) + Electrocoagulation | Flexible dual system for tissue removal and permanent hair removal. |
| Frequency in Hair Removal Mode | 1.695 MHz (Megahertz) | High frequency that cleanly and permanently destroys the dermal papilla. |
| Frequency in Coagulation Mode | 18 kHz (Kilohertz) | Instant thermal cauterization that cuts blood vessels and prevents bleeding. |
| Depth and Impact Adjustment | Individually adjustable on panel | Strict calibration to adapt to the sensitivity and size of the lesion. |
| Total Power Consumption | ≤ 15 W (Power Supply: 220-240V / 50 Hz) | Insignificant electrical consumption; cool and safe hardware in a clinical setting. |
| Electrical Isolation | Protection Class IP20 | Shielded structure against short circuits with integrated safety locks. |
| Tabletop Dimensions | 300 * 230 * 60 mm (Net) | Extra-flat modular design, cleanly combinable with the T Series. |
Technical Application Protocol in the Booth (Step-by-Step):
- Preparation and Sanitization of the Booth: Thoroughly clean, disinfect, and prepare the skin area to be treated. For lesion electrocoagulation mode, administer topical or infiltrated local anesthesia according to your center's clinical protocol.
- Exclusive Electroepilation Phase (Thermolysis): Select the handpiece for electroepilation needles. Verify that the patient's hair has a strict length of 3 to 5 mm. Insert the disposable needle parallel to the hair shaft until it flexibly reaches the base of the follicle. Press the pedal to release the **1.695 MHz** express pulse. Remove the destroyed hair cleanly with tweezers; it should slide out impeccably without mechanical resistance.
- Surgical Electrocoagulation Phase: Switch to the ablative electrode handpiece and install the specialized nozzle from the kit according to the size of the benign lesion. Calibrate the parameters on the screen. Move the electrode over the base of the neoplasm, activating the **18 kHz** current: the thermal arc will immediately cauterize the tissues and vessels. Cleanly remove the intact biological specimen and place it in the transport container for histological analysis.
- Post-Treatment Aesthetic Closure: Apply an antiseptic solution and a protective epithelizing ointment over the small, protective residual scab. The patient can immediately resume their daily routine. Disinfect the handpieces and strictly dispose of used needles in the biohazard material container.
💡 Pro Tip: The most common operational error when using the T-18 system for electrolysis hair removal is to exert mechanical traction with the tweezers on the hair at the same time as inserting the needle or before the electrical pulse ends, for fear of prolonging the treatment. If you pull the hair by force, you will break the hair shaft but leave the papilla and biological matrix intact, causing the hair to grow back cleanly and frustrating the objective of the session. **Flexibly insert the needle deep into the follicle, activate the pedal to emit the supersonic radiofrequency, and wait for the thermal energy to denature the papilla; the hair should slide out impeccably and without any resistance.** This strict methodological rigor will ensure 100% effectiveness, excellent patient comfort, and consolidate your business's international reputation.
Engineering Guarantee and Technical Support: Alvi Prague includes a comprehensive official maintenance manual with this device and offers advanced professional training on demand with certification, validating the operational competencies of its technicians in Spain.
Click "Add to Cart," introduce the millimeter precision of the Alvi Prague T-18 Station into your medical-aesthetic catalog, optimize the cost of your consumables, and offer your patients definitive solutions for tissue removal and high-fidelity clinical hair removal.
Share
