Neo-Light TL-500 Neodymium YAG Laser
Neo-Light TL-500 Neodymium YAG Laser
SKU:Neo-Light TL-500
VAT not included
Couldn't load pickup availability
Premium Q-Switched Platform for Tattoo Removal, Permanent Makeup, and Carbon Peeling
Boost the prestige of your salon, meet the extremely high demand for micropigmentation removal, and offer express epidermal renewal treatments with the Alvi Prague Neo-Light TL-500 Nd:YAG Neodymium Laser. Developed under strict engineering standards in the Czech Republic by the prestigious firm Alvi Prague, this premium medical-aesthetic device represents a radical and non-ablative solution for the destruction of complex pigments and the correction of skin imperfections. By operating with ultra-short, high-density pulses, this hardware penetrates tissues flexibly without altering the superficial integrity of the skin or vaporizing healthy tissues.
With a robust, ergonomic, and compact chassis measuring **44 x 40.5 x 33.4 cm** (net weight of 20 kg and gross weight of 28 kg with protective packaging of 55.5 x 47.5 x 57.5 cm), the Neo-Light TL-500 model is ideal for flexible placement on any advanced technical table. Its internal mechanical stability is backed by a powerful **two-stage cooling system (water / air)** that maintains components within ideal temperature ranges. The hardware connects directly to **220-240 V / 50 Hz** networks with highly efficient energy consumption of **500 W**, holding **Class 4 laser safety and IP20 protection** certification endorsed by the European Union.
Advanced Synergistic Effect: Selective Photothermolysis and Micromolecular Explosion
The major drawback of traditional removal methods is the formation of burn scars, acute pain, or long downtime periods. The Neo-Light TL-500 excellently solves this through selective photothermolysis: it emits a narrow, concentrated beam in a flexible range of **532 nm to 1320 nm** that penetrates up to 8 mm deep. Upon reaching the tattoo pigment, the particles instantly absorb the photonic energy, undergoing rapid heating that triggers a **micromolecular explosion**. The pigment is sharply fragmented into microscopic particles that are absorbed by macrophages and naturally eliminated through the lymphatic system, clarifying the design before the specialist's eyes.
Specialized Wavelengths and Consumable-Free Spot Flexibility
The hardware comes completely ready to operate from day one in your dermo-aesthetic business, controlling the beam diameter between **1 and 8 mm** thanks to its interchangeable technical nozzles that require no consumables per shot:
- 1064 nm Nozzle: Precisely calibrated for the impeccable destruction of dark and black pigments (monochromatic tattoos, dark eyebrow outlines, and deep permanent makeup).
- 532 nm Nozzle: Specifically designed to act on light and colored chromophores, flexibly removing red, brown, orange inks, and superficial epidermal pigmentations.
- 1320 nm Module (Activated Carbon Peeling): Molecular synergy that interacts with a carbon nanoparticle mask. When the laser passes, the carbon rapidly evaporates, sweeping away dead cells, regulating sebum, and cleanly cleansing pores for an instant lifting effect.
High-Fidelity Aesthetic and Dermatological Indications
- Complex Tattoo Removal: Cleanly destroys monochromatic and colored inks, even those with resistant metallic oxides, in a rapid course of 4 to 5 sessions.
- Permanent Makeup Removal: Safely and sharply fades defective micropigmentations on eyebrows, lips, and eyes in just 2 or 3 treatments.
- Treatment of Pigmentation Spots and Post-Acne Marks: Homogenizes the natural relief and color of the epidermis, stimulating the internal production of collagen and cellular water.
- Hollywood Peel (Holographic Carbon Peel): Deep cleansing that reduces pore size, mitigates active acne, and provides clear tissue rejuvenation with no recovery time.
Technical Specifications Table and Official Parameters
| Hardware Specification | Official Value / Configuration | Operational Performance in Your Salon |
|---|---|---|
| Laser Technology Type | Q-Switched Nd:YAG Neodymium Laser | Non-ablative pulsed emission based on yttrium aluminum garnet crystal. |
| Optical Wavelengths | 532 nm / 1064 nm / 1320 nm | Flexible versatility to treat full color spectrums and rejuvenation. |
| Maximum Energy Density | 1500 $mJ / cm^2$ | High photonic fluence to pulverize the most resistant oxide pigments. |
| Pulse Duration | 10 ns (Nanoseconds) | Ultra-short express emission that prevents burns and minimizes peripheral thermal damage. |
| Pulse Frequency | From 1 to 12 Hz (Shots per second) | Adjustable working speed that streamlines sweeping on large-scale tattoos. |
| Spot Diameter | Adjustable from 1 ~ 8 mm | Millimetric focus adapted to ink density and anatomical relief. |
| Handpiece Resource | Up to 500,000 total pulses | Certified factory warranty of 6 months or 300,000 shots (whichever comes first). |
| Power Consumption | 500 W | Low operational maintenance cost; high net profitability for your stock. |
Technical Application Protocol in the Salon (Step by Step):
- Tissue Evaluation and Preparation: Clean the patient's skin thoroughly. Determine the age, saturation, and depth of the ink. For deep or extensive tattoos, apply a flexible local anesthetic cream and remove it perfectly before firing.
- Optical Nozzle Selection: Sharply screw the appropriate nozzle onto the handpiece (1064 nm for blacks/blues, 532 nm for reds/browns, or the special nozzle if applying the carbon dioxide mask for holographic peeling).
- Hardware Configuration and Biosafety: Turn on the Neo-Light TL-500 system. **The use of Class 4 laser protective eyewear is strictly mandatory for both the practitioner and the patient**. Adjust the frequency (1-12 Hz) and energy density on the 8-inch touch screen according to the tolerated threshold.
- Express Execution and Post-Session Care: Position the handpiece perpendicularly and execute shots smoothly. After pigment fragmentation, clean the area thoroughly and apply a molecular soothing gel or healing cream. Clearly instruct the patient to avoid the sun and schedule the next session with a flexible interval of 4 to 6 weeks.
💡 Pro Tip: When operating the Neo-Light TL-500 for dark tattoo removal with the 1064 nm nozzle, the unequivocal clinical indicator of effective photothermolysis is the instant appearance of superficial whitening over the pigment, technically known as *frosting* (caused by the rapid release of gas microbubbles after the micromolecular explosion). If, after the first linear pass, you notice that the frosting is opaque and sharp, **do not fire again on the same quadrant in the same session**. Re-irradiating a whitened area will thermally saturate the epidermis, breaking the elastic skin barrier and generating blisters, fibrosis, or permanent pigmentation changes. Allow the lymphatic system to act cleanly during the rest weeks; this will optimize the lifespan of your emitter's 500,000 pulses and consolidate the clinical success of your business internationally.
Estimated delivery time: 7 to 10 business days directly to the door of your tattoo studio, medical spa, or advanced aesthetic center with a certified 18-month warranty on the internal configuration!