Class B Autoclave Standard Line 12 L with thermal printer and USB
Class B Autoclave Standard Line 12 L with thermal printer and USB
SKU:127652
VAT not included
Couldn't load pickup availability
Lafomed Standard Line 12 L Class B Medical Autoclave | With Thermal Printer and USB for Clinics, Aesthetics, and Tattooing
Ensure absolute hospital-grade sterilization, rigorously comply with current health regulations, and optimize safety in your work area with the Lafomed Standard Line 12 Liter Class B Medical Autoclave. This structural electromechanical equipment of intermediate format has been specifically developed to act as a saturated steam sterilization system with fractional vacuum, designed to cleanly, clearly, and safely eliminate 100% of spores, viruses, and bacteria from all types of clinical, surgical, dental, and aesthetic instruments.
Equipped with an intuitive LED screen, **integrated thermal printer**, USB port for digital cycle traceability, and a cylindrical 304 stainless steel chamber with capacity for a basket with 3 included trays, this autoclave is consolidated as the structural and indispensable equipment in dental clinics, medical offices, laboratories, advanced aesthetic centers, and tattoo studios that demand high capacity in an optimized external size.
Medical Class B: Total Sterilization of Hollow, Porous, and Wrapped Bodies
The biggest drawback of using Class N autoclaves or common thermal sterilizers in aesthetic or health centers is that they fail to eliminate microorganisms inside hollow tools (such as turbines, contra-angles, cannulas, or needles) or in porous materials (such as gauze or textile fields), and do not allow the processing of bagged instruments, generating critical risks of cross-contamination. The Lafomed Standard Line 12 L autoclave solves this excellently thanks to its **high-performance vacuum pump**. By performing fractional vacuum cycles (configurable from 1 to 10 times), it cleanly extracts air from inside the chamber, allowing steam to penetrate elastically and impeccably into the most hidden pores and cavities of packaged tools.
Key Benefits of the Lafomed Standard Line 12 L Autoclave
- Optimized 12-Liter Capacity: Its cylindrical chamber, 20 cm in diameter and 33 cm deep, can accommodate a structural basket with 3 trays, ideal for processing medium volumes of instruments without occupying excessive countertop space.
- High-Fidelity Dual Traceability (Printer + USB): Neatly records each sterilization cycle. The integrated thermal printer issues a physical ticket (without ink) for the technical passport, while the USB port automatically saves cycle records digitally on a flash drive.
- Express Cycle of Only 8 Minutes: Its shortest program (134 °C Solid) flawlessly processes instruments in a record time of 8 minutes, including the thermal drying phase, ideal for optimizing material rotation in the cabin between appointments.
- 6 Precision Automatic Programs: Includes 4 ready-to-use sterilization programs and the 2 most demanding essential clinical control tests in the sector: Bowie & Dick / Helix Test and the Vacuum Test.
- Integrated Double Tank and Structural Safety: Features independent tanks for clean (distilled) and used water with an express front emptying system. Incorporates a real-time error self-diagnosis system, a high-quality bacterial filter (replaceable every ~150 cycles), and a double door locking mechanism.
Technical Programs and Indicative Times Table
| Technical Program | Load Condition | Exposure Time (Indicative) |
|---|---|---|
| 121° Solid | Unwrapped | 24 min |
| 121° Universal | Wrapped and unwrapped | 35 min |
| 134° Solid (Express Cycle) | Unwrapped | 8 min (with drying) |
| 134° Universal | Wrapped and unwrapped | 19 min |
| B&D Test (Bowie & Dick) | B&D / Helix Test Pack | 4 min |
| Vacuum Test | Technical Vacuum Test | 15 min |
*The indicated times correspond to the operational plateau phase after the internal chamber's pre-heating.
Technical Specifications of the Equipment:
- Medical Classification: Certified Class B (Complies with the requirements of European standard BS EN 13060:2014+A1:2018).
- Useful Chamber Capacity: 12 Liters (Physical dimensions: Ø 20 cm × 33 cm deep).
- Power and Voltage: 1.95 kW — 230 V — 50/60 Hz (Excellent stability and thermal performance).
- Maximum Working Temperature: 137 °C.
- Maximum Working Pressure: 240 kPa (Design pressure: -0.1 / 0.27 MPa).
- Structural Safety Valve: Opening calibrated at 0.24 MPa (Opening range 0.24–0.26 MPa).
- User Menu Configuration: Time control from 4 to 60 min, thermal drying from 1 to 25 min, and from 1 to 10 vacuum cycles.
- Unit Dimensions: 64 × 44 × 36 cm (Optimal design for standard countertops).
- Net Weight: 51 kg (Packaged weight: 59 kg — Box dimensions: 73 × 52 × 43 cm).
- Chamber Material: Medical-grade 304 stainless steel.
- Available Colors: Elegant white or black finish.
- Clinical Grade Certifications: CE 1023, ISO 13485. Strictly complies with international health requirements.
- Official Premium Warranty: Standard 24-month warranty. Possibility to extend for an additional 12 months (total 36 months) if a paid technical inspection is carried out at an authorized service center before the end of the basic period (applicable to equipment purchased since 22/08/2022). Includes free official Technical Passport.
Complete Structural Package Contents:
- Lafomed Standard Line 12 L Autoclave with integrated Thermal Printer.
- Structural metal basket with 3 perforated aluminum trays.
- Tray holder and tray extractor/safety grip.
- Flexible hose for express drainage of used water.
- Power cable.
- Spare fuse.
- Instruction manual (English) and official Clinical Control Technical Passport.
Technical Protocol for Use and Quality Control (Instructions for Use):
- Loading and Hydraulic Inspection: Cleanly check that the distilled water tank is full. Insert the previously washed, disinfected, and dried instruments (either packaged or loose) into the basket trays, distributing the weight evenly and flexibly without overcrowding the material.
- Express Cycle Selection: Close the door clearly until the double door lock engages. Select the appropriate program on the LED screen according to the load (e.g., 134° Universal for bagged tools). The program lights will clearly validate the selection.
- Vacuum and Drying Operating Phase: The 12 L autoclave will impeccably execute the fractional pre-vacuum, molecular sterilization, and thermal drying phases. Upon completion, the thermal printer will clearly issue the physical ticket of technical cycle validation for your records.
- Drainage and Technical Maintenance: Use the included tray extractor to safely remove hot material without mechanical burns. Remember to perform the express front emptying of the used water tank when indicated by the system and flexibly replace the high-quality bacterial filter approximately every 150 cycles to protect the purity of the incoming air.
💡 Pro Tip: The most common mistake in aesthetic centers, clinics, and tattoo studios is performing sterilization cycles without archiving the physical receipts from the autoclave, which invalidates the legal security of the center in the event of a health or epidemiological inspection. To protect your business with an excellent and high-fidelity protocol, **keep a daily physical record using the Lafomed Standard Line 12 L's thermal printer**. Paste the printed ticket from each cycle into a numbered logbook next to the batch number of the instrument bags used that day. At the end of the day, save the digital data to a USB flash drive cleanly. This dual analog and digital traceability system demonstrates impeccable asepsis control, complies with international ISO 13485 standards, and guarantees a 100% professional and unbreakable standard.
Click "Add to Cart," protect the health of your patients and clients, comply with current legal regulations, and equip your center with fractional vacuum technology, absolute traceability, and the 12-Liter versatility of Lafomed's Standard line.