Skip to product information
1 of 18

Class B Premium Line 18L Autoclave with Thermal Printer and USB

Class B Premium Line 18L Autoclave with Thermal Printer and USB

SKU:115391

Regular price €1.680,00
Regular price Sale price €1.680,00
Sale Sold out
Shipping calculated at checkout.

VAT not included

Quantity

Lafomed Premium Line LFSS18AA 18 L Class B Medical Autoclave | With Touch Panel and Thermal Printer for Clinics, Aesthetics, and Tattoo Shops

Guarantee absolute hospital-grade sterilization, rigorously comply with current health regulations, and optimize safety in your work area with the Lafomed Premium Line LFSS18AA 18-liter Class B Medical Autoclave. This high-end structural electromedical equipment has been developed to direct specifications, incorporating exclusive advanced engineering solutions. It acts as a saturated steam sterilization system with fractional vacuum in an intermediate volume, designed to cleanly, clearly, and safely eliminate 100% of spores, viruses, and bacteria from all types of clinical, surgical, and aesthetic instruments.

Equipped with a highly sensitive touch panel, an integrated thermal printer, a USB port for digital traceability of cycles, and a premium-design cylindrical chamber with capacity for trays of different formats, this autoclave consolidates its position as essential structural equipment for dental clinics, medical practices, laboratories, advanced beauty salons, and tattoo studios that demand maximum performance.

Medical Class B: Total Sterilization of Hollow, Porous, and Wrapped Items

The main drawback of using Class N autoclaves or common thermal sterilizers in healthcare or aesthetic centers is that they cannot eliminate microorganisms inside hollow tools (such as turbines, contra-angles, cannulas, or needles) or porous materials (such as gauze or textile drapes), nor do they allow processing bagged instruments, leading to critical cross-contamination risks. The Lafomed Premium Line 18 L autoclave solves this with its high-performance vacuum pump. By performing fractional vacuum cycles (configurable from 1 to 10 times), it cleanly extracts air from inside the chamber, allowing steam to penetrate flexibly and flawlessly into the deepest pores and cavities of bagged tools.

Key Benefits of the Lafomed Premium Line 18 L Autoclave

  • Touch Panel and High-Fidelity Interface: Full control of parameters via a modern, intuitive touch panel with an interface available in Polish and English, facilitating flexible and fluid navigation through technical menus.
  • Automated Dual Traceability (Printer + USB): Neatly records each sterilization cycle. The integrated thermal printer issues a physical receipt (inkless) for the technical passport, while the USB output saves data in an exportable digital format.
  • 8 Automatic Programs and Clinical Tests: Includes ready-to-use sterilization programs and the 3 most demanding clinical control tests in the sector: Bowie & Dick, Helix Test, and Vacuum Test, in addition to an automated self-cleaning program.
  • Advanced Personalized Control: Allows manual and flexible configuration of the temperature range (105–134 °C), sterilization time (4 to 60 min), drying phase (1 to 25 min), and vacuum cycles (1 to 10 times) for specific laboratory or university protocols.
  • Clinical Grade Safety and Filtration: Incorporates a high-quality bacterial filter to ensure the purity of incoming air, a double mechanical locking system on the door, and a robust, weld-free 304 stainless steel chamber.

Table of Technical Parameters and Operating Programs

Technical Parameter Technical Control Range Operational Application
Sterilization Temperature 105 °C to 134 °C Suitable for heat-sensitive materials, textiles, and surgical steel.
Exposure Time 4 – 60 minutes Adjustable according to the porosity level and volume of the load.
Thermal Drying Time 1 – 25 minutes Ensures 100% dry bags and instruments at the end of the cycle.
Vacuum Cycles (Vacuum Times) 1 – 10 repetitions Clear air extraction in highly complex hollow bodies.
Working Pressure 0.21 – 0.23 MPa Stabilized pressure for optimal molecular penetration.

*The equipment has pre-configured express automatic programs for solid, porous, concave instruments and prions at 121 °C and 134 °C.

Technical Specifications of the Equipment:

  • Medical Classification: Class B (European Standard PN‑EN 13060:2004 + A2:2010).
  • Usable Chamber Capacity: 18 Liters (Physical dimensions: Ø 25 cm × 35 cm deep).
  • Power and Voltage: 2.4 kW — 230 V — 50 Hz.
  • Unit Dimensions: 65 × 50 × 43 cm.
  • Included Tray Dimensions: 1 tray of 29 × 18.5 × 2 cm and 1 tray of 29 × 22 × 2 cm.
  • Net Weight: 53 kg (Packaged weight: 61 kg).
  • User Interface: LCD screen (6 × 4.25 cm) integrated into a capacitive touch panel.
  • Clinical Grade Certifications: CE 1023, ISO 13485.
  • Official Premium Warranty: Standard 24-month warranty. Possibility to extend for an additional 12 months (total 36 months) through a paid technical inspection at an authorized service center before the end of the initial period. (Applies to equipment purchased from 01/04/2022). Includes free official Technical Passport.

Complete Structural Package Contents:

  • Lafomed Premium LFSS18AA 18 L Autoclave with integrated Thermal Printer.
  • 2 perforated aluminum trays of different dimensions.
  • Structural tray support and safety extraction handle.
  • Flexible hose for used water drainage.
  • Power cable.
  • Spare fuse.
  • Instruction manual (English and Polish) and official Technical Control Passport.

Technical Protocol for Use and Quality Control (Instructions for Use):

  1. Loading and Hydraulic Inspection: Clearly verify that the distilled water tank is full. Place previously washed, disinfected, and bagged instruments onto the trays, distributing the weight evenly and flexibly without overlapping the packages.
  2. Express Cycle Selection: Close the door cleanly until the double mechanical lock engages. Select the appropriate program on the touch panel according to the load. You can use advanced functions to optimize the daily performance of the clinic.
  3. Operational Vacuum and Drying Phase: The 18 L autoclave will flawlessly execute the fractional pre-vacuum, sterilization, and thermal drying phases using residual heat. Upon completion, the thermal printer neatly issues the physical validation ticket for the cycle.
  4. Drainage and Safe Storage: Use the extraction handle to remove the hot trays without suffering mechanical burns. Store the sterilized packages cleanly in a dry place. When indicated by the system, quickly drain the used water through its front drainage outlet.
💡 Pro Tip: The most common mistake in high-turnover centers and salons is performing sterilization cycles without archiving the physical receipts from the autoclave, which invalidates the legal security of the center in the event of a health inspection. To protect your business with an excellent and high-fidelity protocol, keep a daily physical record using the Lafomed LFSS18AA thermal printer. Attach the printed ticket from each cycle to a numbered logbook next to the lot number of the surgical or aesthetic instrument bags used that day. At the end of the day, cleanly save the digital data to a USB stick. This dual analog and digital traceability system demonstrates impeccable aseptic control, complies with international ISO 13485 standards, and guarantees a 100% professional and unbreakable standard.

Click "Add to cart," protect the health of your patients or clients, comply with current legal regulations, and equip your center with the touch panel technology, advanced fractional vacuum, and ideal 18-liter format of the Lafomed Premium range.